Professional 4-channel radio controller for automation, tail lifts and hydraulic platforms
AK-C211008 radio receiver is a professional four-channel wireless controller designed for remote control of devices powered by 12–36 V DC.
Thanks to four independent relays, a wide supply voltage range and an external long-range antenna, it is suitable for both industrial and automotive applications.
| Model | AK-C211008 |
| Number of channels | 4 |
| Supply voltage | 12–36 V DC |
| Radio frequency | 433 MHz |
| Operating modes | 6 |
| Output type | NO, COM, NC – potential-free |
| Relays | 4 × Songle SRD-09VDC-SL-C, up to 10 A |
| Standby current | Below 6 mA |
| Receiver sensitivity | Down to -105 dBm |
| Antenna | External 433 MHz antenna with SMA connector |
| Operating temperature | -40°C to +80°C |
| Protection rating | IP20 |
| Dimensions | 95 × 62 × 28 mm |
| Weight | Module with antenna and housing 99.5g, 2x remote controls 57g |
| Open area | Approx. 150–300 m with clear line of sight |
| Industrial areas, yards and car parks | Approx. 80–150 m |
| Inside halls, buildings or vehicles | Approx. 30–80 m |
Actual range depends on antenna position, terrain, obstacles, radio interference and signal propagation conditions.
Unlike many basic controllers available on the market, the AK-C211008 model is equipped with high-quality components designed to provide stable and reliable operation.
We also offer professional installation, configuration and commissioning of radio controllers for tail lifts and hydraulic platforms.
The service includes:
Installation is carried out in Mińsk Mazowiecki, Poland.
We provide professional technical advice and assistance in selecting the appropriate solution for a specific tail lift or platform model.
| Product | AK-C211008 Radio Receiver 4CH Controller for Tail Lift 2 Remote Controls |
| Model | AK-C211008 |
| Supply voltage | 12–36 V DC |
| Radio frequency | 433 MHz |
| Number of channels | 4 |
| Outputs | NO, COM, NC – potential-free |
| Relays | 4 × Songle SRD-09VDC-SL-C, up to 10 A |
| Operating temperature | -40°C to +80°C |
| Protection rating | IP20 |
| ✓ | Use only with 12–36 V DC power systems. |
| ✓ | Do not exceed the maximum supply voltage of 36 V DC. |
| ✓ | Before connection, check supply polarity, output wiring and the parameters of the controlled equipment. |
| ✓ | Do not exceed the permitted load of the relays and take the characteristics of the connected load into account. |
| ✓ | Do not use the unit if the housing, wiring, connectors, antenna or other components are damaged or show signs of overheating. |
| ✓ | Disconnect the power supply before installation, removal or modification of the wiring. |
| ✓ | After installation, test all functions while maintaining a safe distance from moving parts of the controlled equipment. |
| ✓ | Do not remove or bypass original interlocks, limit switches, sensors or emergency stop devices. |
| ✓ | Before activation, make sure that no person or obstacle is present in the operating area. |
| ✓ | Remote control functions should be assigned clearly to reduce the risk of accidental activation of the wrong function or direction. |
| ✓ | After any change to receiver or remote control configuration, retest all channels and safety functions. |
| Power supply | 12–36 V DC |
| Relay outputs | Potential-free NO, COM and NC contacts |
| Protection | Fuse in the circuit |
| Before commissioning | Check polarity, wiring, fuse condition, channel configuration and ensure there are no short circuits. |
| Operating temperature | -40°C to +80°C |
| Protection rating | IP20 |
The product is a control system component intended for integration into a properly designed electrical installation and automation system.
Installation must be carried out in accordance with the technical documentation of the controlled equipment while preserving its original safeguards and safety functions.
For tail lifts, hydraulic platforms, machines, winches and other equipment involving hazardous movement, installation and commissioning should be performed by persons with suitable qualifications or experience in electrical installations and automation.
Use only as intended, within the 12–36 V DC supply range and with all required safety systems of the controlled equipment retained.
| Manufacturer (Private Label) (EU) 2023/988 (GPSR) | |
|---|---|
| Name: | Superelektronika sp. z o.o. |
| Address: | ul. gen. K. Sosnkowskiego 26/83 05-300 Mińsk Mazowiecki, Poland |
| E-mail: | sklep@superelektronika.pl |
| Responsible Person (EU) 2023/988 (GPSR) | |
| Name: | Superelektronika sp. z o.o. |
| Address: | ul. gen. K. Sosnkowskiego 26/83 05-300 Mińsk Mazowiecki, Poland |
| E-mail: | sklep@superelektronika.pl |
You might also like